天天日天天干天天操,日本午夜电影网,日本黄色大片在线观看,欧美A久久

產(chǎn)品目錄

服務(wù)中心

產(chǎn)品展示

您現(xiàn)在的位置:產(chǎn)品展示 >> 閥門(mén)系統(tǒng) >> 氣動(dòng)閥 >> 閥PHS520S-8-220V-D新型PHS520S-02-220V-D

閥PHS520S-8-220V-D新型PHS520S-02-220V-D

  • 型   號(hào):
  • 價(jià)   格:390

閥PHS520S-8-220V-D新型PHS520S-02-220V-D
閥門(mén)系統(tǒng)(閥島、
現(xiàn)場(chǎng)總線連接、電磁閥、換向閥、氣動(dòng)閥、機(jī)械閥、電磁閥組、壓力調(diào)節(jié)閥、氣動(dòng)比例閥、止回閥、節(jié)流閥、單向閥、安全閥、溢流閥),氣源處理單元(噴霧潤(rùn)滑器(油霧器)、過(guò)濾器、調(diào)壓閥、過(guò)濾器調(diào)壓閥、分氣塊、換向閥、壓力表)、傳感器(接近傳感器、磁接近開(kāi)關(guān)、位移傳感器、壓力傳感器、壓力開(kāi)關(guān));氣動(dòng)連接件(快接插頭、空氣

分享到:


閥PHS520S-8-220V-D新型PHS520S-02-220V-D  

     電動(dòng)閥通常由電動(dòng)執(zhí)行機(jī)構(gòu)和閥門(mén)組成。電動(dòng)閥使用電能作為動(dòng)力來(lái)通過(guò)電動(dòng)執(zhí)行機(jī)構(gòu)來(lái)驅(qū)動(dòng)閥門(mén),實(shí)現(xiàn)閥門(mén)的開(kāi)關(guān)動(dòng)作。從而達(dá)到對(duì)管道介質(zhì)的開(kāi)關(guān)目的。電動(dòng)閥門(mén)動(dòng)作力距比普通閥門(mén)大,電動(dòng)閥門(mén)開(kāi)關(guān)動(dòng)作速度可以調(diào)整,結(jié)構(gòu)簡(jiǎn)單,易維護(hù),可用于控制空氣、水、蒸汽、各種腐蝕性介質(zhì)、泥漿、油品、液態(tài)金屬和放射性介質(zhì)等各種類型流體的流動(dòng)。

    氣動(dòng)閥門(mén)就是借助壓縮空氣驅(qū)動(dòng)的閥門(mén)。利用壓縮空氣推動(dòng)執(zhí)行器內(nèi)多組組合氣動(dòng)活塞運(yùn)動(dòng),傳力給橫梁和內(nèi)曲線軌道的特性,帶動(dòng)空芯主軸作旋轉(zhuǎn)運(yùn)動(dòng),壓縮空氣氣盤(pán)輸至各缸,改變進(jìn)出氣位置以改變主軸旋轉(zhuǎn)方向,根據(jù)負(fù)載(閥門(mén)7)所需旋轉(zhuǎn)扭矩的要求,可調(diào)整氣缸組合數(shù)目,帶動(dòng)負(fù)載(閥門(mén))工作。氣動(dòng)閥可用于控制空氣、水、蒸汽、各種腐蝕性介質(zhì)、泥漿、油品、液態(tài)金屬和放射性介質(zhì)等各種類型流體的流動(dòng)。

電動(dòng)閥與氣動(dòng)閥各自的優(yōu)勢(shì)

1:氣動(dòng)閥對(duì)氣體介質(zhì)和小管徑液體效果好,成本低,維護(hù)方便。缺點(diǎn):受空壓氣壓力波動(dòng)的影

響,在北方冬季易受空壓氣含水影響,造成傳動(dòng)部分凍結(jié)、不動(dòng)作。一般氣動(dòng)要比電動(dòng)快,電動(dòng)的都是手電兩用的。而氣動(dòng)要手、氣兩用的價(jià)格比較高。

2:電動(dòng)閥對(duì)液體介質(zhì)和大管徑氣體效果好,不受氣候影響。不受空壓氣的壓力影響。缺點(diǎn):成本高、在潮濕環(huán)境不好。

3、電動(dòng)閥動(dòng)作慢電動(dòng)閥能做到防爆的品牌不是很多;氣動(dòng)閥動(dòng)作迅速,防爆相對(duì)來(lái)說(shuō)價(jià)格比電動(dòng)底

(關(guān)鍵氣動(dòng)閥配什么附件,配附件就會(huì)比電動(dòng)閥貴)。

4、電動(dòng)閥門(mén)用于一些大管徑的地方,因?yàn)闅鈩?dòng)很難做到但是電動(dòng)閥門(mén)的穩(wěn)定性不如氣動(dòng)開(kāi)關(guān)速度慢執(zhí)行機(jī)構(gòu)長(zhǎng)時(shí)間會(huì)出現(xiàn)卡齒現(xiàn)象氣動(dòng)閥門(mén)開(kāi)關(guān)速度快精度高但是需要穩(wěn)定的氣源。

閥PHS520S-8-220V-D新型PHS520S-02-220V-D 

   氣動(dòng)調(diào)節(jié)閥安裝原則

    (1)氣動(dòng)調(diào)節(jié)閥安裝位置,距地面要求有一定的高度, 閥的上下要留有一定空間,以便進(jìn)行閥的

拆裝和修理。對(duì)于裝有氣動(dòng)閥門(mén)定位器和手輪的調(diào)節(jié)閥,必須保證操作、觀察和調(diào)整方便。

    (2)調(diào)節(jié)閥應(yīng)安裝在水平管道上,并上下與管道垂直,-般要在閥下加以支撐,保證穩(wěn)固可靠。

對(duì)于特殊場(chǎng)合下,需要調(diào)節(jié)閥水平安裝在豎直的管道上時(shí),也應(yīng)將調(diào)節(jié)閥進(jìn)行支撐(小口徑調(diào)節(jié)閥除外)。安裝時(shí),要避免給調(diào)節(jié)閥帶來(lái)附加應(yīng)力)。

    (3)調(diào)節(jié)閥的工作環(huán)境溫度要在(-30~+ 60)相對(duì)濕度不大于95% 95%,相對(duì)濕度不大于95%。  

(4)調(diào)節(jié)閥前后位置應(yīng)有直管段,長(zhǎng)度不小于10倍的管道直徑(10D),以避免閥的直管段太短而

影響流量特性。    

(5)調(diào)節(jié)閥的口徑與工藝管道不相同時(shí),應(yīng)采用異徑管連接。在小口徑調(diào)節(jié)閥安裝時(shí),可用螺紋

連接。閥體上流體方向箭頭應(yīng)與流體方向-致。

   (6)要設(shè)置旁通管道。目的是便于切換或手動(dòng)操作,可在不停車情況下對(duì)調(diào)節(jié)閥進(jìn)行檢修。

   (7)調(diào)節(jié)閥在安裝前要清除管道內(nèi)的異物,如污垢、悍渣等。

    常見(jiàn)故障及處理

   調(diào)節(jié)閥不動(dòng)作

首先確認(rèn)氣源壓力是否正常,查找氣源故障。如果氣源壓力正常,則判斷定位器或電/氣轉(zhuǎn)換器

的放大器有無(wú)輸出;若無(wú)輸出,則放大器恒節(jié)流孔堵塞,或壓縮空氣中的水分聚積于放大器球閥處。

用小細(xì)鋼絲疏通恒節(jié)流孔,清除污物或清潔氣源。

    如果以上皆正常,有信號(hào)而無(wú)動(dòng)作,則執(zhí)行機(jī)構(gòu)故障或閥桿彎曲,或閥芯卡死。遇此情況,必

須卸開(kāi)閥門(mén)進(jìn)一步檢查 。

調(diào)節(jié)閥卡堵

  如果閥桿往復(fù)行程動(dòng)作遲鈍,則閥體內(nèi)或有黏性大的物質(zhì),結(jié)焦堵塞或填料壓得過(guò)緊,或聚四

氟乙烯填料老化,閥桿彎曲劃傷等。調(diào)節(jié)閥卡堵故障大多出現(xiàn)在新投入運(yùn)行的系統(tǒng)和大修投運(yùn)初

期,由于管道內(nèi)焊渣、鐵銹等在節(jié)流口和導(dǎo)向部位造成堵塞從而使介質(zhì)流通不暢,或調(diào)節(jié)閥檢修中填料過(guò)緊,造成摩擦力增大,導(dǎo)致小信號(hào)不動(dòng)作、大信號(hào)動(dòng)作過(guò)頭的現(xiàn)象。

       遇到此類情況,可迅速開(kāi)、關(guān)副線或調(diào)節(jié)閥,讓贓物從副線或調(diào)節(jié)閥處被介質(zhì)沖跑。另外還可

以用管鉗夾緊閥桿,在外加信號(hào)壓力的情況下,正反用力旋動(dòng)閥桿,讓閥芯閃過(guò)卡處。若不能解決

問(wèn)題,可增加氣源壓力、增加驅(qū)動(dòng)功率反復(fù)上下移動(dòng)幾次,即可解決問(wèn)題。如果還是不能動(dòng)作,則

需要對(duì)控制閥做解體處理,當(dāng)然,這一工作需要很強(qiáng)的專業(yè)技能,-定要在專業(yè)技術(shù)人員協(xié)助下完

成,否則后果更為嚴(yán)重。

PHS520C-8-110V-DL 

PHS520C-8-110V-D-L 

PHS520C-8-110V-DL-L 

PHS520C-8-12V-D 

PHS520C-8-12V-D-L 

PHS520C-8-240V-D V

PHS520C-8-240V-DL 

PHS520C-8-240V-D-L

PHS520C-8-240V-DL-L 

PHS520C-8-24AC-D 

PHS520C-8-24AC-DL 

PHS520C-8-24AC-D-L 

PHS520C-8-24AC-DL-L 

PHS520C-8-24V-D 

PHS520C-8-24V-DL

PHS520C-8-24V-D-L 

PHS520D-8 

PHS520D-8-110V-D

PHS520D-8-110V-DL 

PHS520D-8-110V-D-L

PHS520D-8-110V-DL-L 

PHS520D-8-12V-D 

PHS520D-8-12V-D-L 

PHS520D-8-240V-D 

PHS520D-8-240V-DL

PHS520D-8-240V-D-L 

PHS520D-8-240V-DL-L

PHS520D-8-24AC-D

PHS520D-8-24AC-DL

PHS520D-8-24AC-D-L

PHS520D-8-24AC-DL-L 

PHS520D-8-24V-D 

PHS520D-8-24V-DL

PHS520D-8-24V-D-L

PHS520D-8-24V-DL-L

PHS520D-8-L 

PHS520E-8 

PHS520E-8-110V-D

PHS520E-8-110V-DL 

PHS520E-8-110V-D-L

PHS520E-8-110V-DL-L 

PHS520E-8-12V-D 

PHS520E-8-12V-D-L 

PHS520E-8-240V-D

PHS520E-8-240V-DL

PHS520E-8-240V-D-L

PHS520E-8-240V-DL-L

PHS520E-8-24AC-

PHS520E-8-24AC-D-L 

PHS520E-8-24V-D 

PHS520E-8-24V-DL 

PHS520E-8-24V-D-L 

PHS520E-8-24V-DL-L 

PHS520-M4 

PHS520-M5

PHS520-M6 

PHS520-M8 

PHS520P-8 

PHS520P-8-110V-D 

PHS520P-8-110V-DL

PHS520P-8-110V-D-L 

PHS520P-8-110V-DL-L

PHS520P-8-12V-D 

PHS520P-8-12V-D-L

PHS520P-8-240V-D

PHS520P-8-240V-DL

PHS520P-8-240V-D-L

PHS520P-8-240V-DL-L 

PHS520P-8-24AC-D

PHS520P-8-24AC-D-L 

PHS520P-8-24V-D

PHS520P-8-24V-DL

PHS520P-8-24V-D-L

PHS520P-8-24V-DL-L 

PHS520P-8-L 

PHS520S-8

PHS520S-8-110V-D

PHS520S-8-110V-DL

PHS520S-8-110V-D-L 

PHS520S-8-110V-DL-L

PHS520S-8-12V-D

PHS520S-8-12V-D-L 

PHS520S-8-240V-D 

PHS520S-8-240V-DL 

PHS520S-8-240V-D-L

PHS520S-8-240V-DL-L 

PHS520S-8-24AC-D V

PHS520S-8-24AC-D-L 

PHS520S-8-24V-D 

PHS520S-8-24V-DL

PHS520S-8-24V-D-L 

PHS520S-8-24V-DL-L

PHS520S-8-L 

PHS520SRK REPAIR KIT, PHS520 PHP520

氣動(dòng)閥操作方法

  1、氣動(dòng)閥操作時(shí)的啟閉方向,一律應(yīng)順時(shí)針關(guān)閉

       2、由于管網(wǎng)中的氣動(dòng)閥,經(jīng)常是人工啟閉,啟閉轉(zhuǎn)數(shù)不宜過(guò)多,就是大口徑閥門(mén)亦應(yīng)在200-600轉(zhuǎn)內(nèi)。

  3、為了便于一個(gè)人的啟閉操作,在管道工壓狀況下,最大啟閉力矩宜為240N-m。

  4、氣動(dòng)閥啟閉操作端應(yīng)為方榫,且尺寸標(biāo)準(zhǔn)化,并面向地面,以便人們從地面上可直接操作。帶輪盤(pán)的閥門(mén)不適用于地下管網(wǎng)。

  5、氣動(dòng)閥啟閉程度的顯示盤(pán)

  a、氣動(dòng)閥啟閉程度的刻度線,應(yīng)鑄造在變速箱蓋上或轉(zhuǎn)換方向后的顯示盤(pán)的外殼上,一律面向地面,刻度線刷上熒光粉,以示醒目;

  b、指示盤(pán)針的材質(zhì)在管理較好的情況下可用不銹鋼板,否則為刷漆的鋼板,切勿使用鋁皮制作;

  c、指示盤(pán)針醒目,固定牢靠,一旦啟閉調(diào)節(jié)準(zhǔn)確后,應(yīng)以鉚釘鎖定。

  6、若氣動(dòng)閥埋設(shè)較深,操作機(jī)構(gòu)及顯示盤(pán)離地面距離≥1.5m時(shí),應(yīng)設(shè)有加長(zhǎng)桿設(shè)施,且固定穩(wěn)牢,以便人們從地面上觀察及操作。也就是說(shuō),管網(wǎng)中的閥門(mén)啟閉操作,不宜下井作業(yè)。

 氣動(dòng)閥注意事項(xiàng)

  1、氣動(dòng)閥門(mén)屬于現(xiàn)場(chǎng)儀表,要求環(huán)境溫度應(yīng)在-25~60℃范圍,相對(duì)濕度≤95%。如果是裝置在露天或高溫場(chǎng)合,應(yīng)采取防水、降溫措施。在有震源的地方要遠(yuǎn)離振源或增加防振措施。

  2、氣動(dòng)閥門(mén)一般應(yīng)垂直裝置,特殊情況下可以傾斜,如傾斜角度很大或者閥本身自重太大時(shí)對(duì)閥應(yīng)增加支承件保護(hù)。

  3、裝置氣動(dòng)閥門(mén)的管道一般不要離地面或地板太高,在管道高度大于2m時(shí)應(yīng)盡量設(shè)置平臺(tái),以利于操作手輪和便于進(jìn)行維修。

  4、氣動(dòng)閥門(mén)裝置前應(yīng)對(duì)管路進(jìn)行清洗,排除污物和焊渣。裝置后,為保證不使雜質(zhì)殘留在閥體內(nèi),還應(yīng)再次對(duì)閥門(mén)進(jìn)行清洗,即通入介質(zhì)時(shí)應(yīng)使所有閥門(mén)開(kāi)啟,以免雜質(zhì)卡住。在使用手輪機(jī)構(gòu)后,應(yīng)恢復(fù)到原來(lái)的空檔位置。

  5、為了使氣動(dòng)閥門(mén)在發(fā)生故障或維修的情況下使生產(chǎn)過(guò)程能繼續(xù)進(jìn)行,調(diào)節(jié)閥應(yīng)加旁通管路。同時(shí)還應(yīng)特別注意,調(diào)節(jié)閥的裝置位置是否符合工藝過(guò)程的要求。

  6、氣動(dòng)閥門(mén)的電氣部分裝置應(yīng)根據(jù)有關(guān)電氣設(shè)備施工要求進(jìn)行。如是隔爆型產(chǎn)品應(yīng)按《爆炸危險(xiǎn)場(chǎng)所電氣設(shè)備裝置規(guī)范》要求進(jìn)行裝置。如現(xiàn)場(chǎng)導(dǎo)線采用SBH型或其它六芯或八芯、外徑為Φ11.3mm左右的膠皮裝置電纜線。在使用維修中,在易爆場(chǎng)所嚴(yán)禁通電開(kāi)蓋維修和對(duì)隔爆面進(jìn)行撬打。同時(shí)在拆裝中不要磕傷或劃傷隔爆面,檢修后要還原成原來(lái)的隔爆要求狀態(tài)。

  7、執(zhí)行機(jī)構(gòu)的減速器拆修后應(yīng)注意加油潤(rùn)滑,低速電機(jī)一般不要拆洗加油。裝配后還應(yīng)檢查閥位與閥位開(kāi)度指示是否相符。

產(chǎn)品報(bào)價(jià)及貨期說(shuō)明: 因工業(yè)液壓、自動(dòng)化各進(jìn)口品牌備件型號(hào)繁多,歐美產(chǎn)品價(jià)格貨期實(shí)時(shí)變化,因此很難實(shí)時(shí)標(biāo)出準(zhǔn)確價(jià)格,故具體產(chǎn)品信息、報(bào)價(jià)及貨期請(qǐng)以我公司報(bào)價(jià)單為準(zhǔn) ,給您帶來(lái)不便敬請(qǐng)諒解!以上信息由上海韋米公布,最終解釋權(quán)歸上海韋米機(jī)電設(shè)備有限公司所有。感謝您的合作,竭誠(chéng)為您服務(wù)。


638476529741235602220.jpg



留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7